显示标签为“water pump”的博文。显示所有博文
显示标签为“water pump”的博文。显示所有博文

2014年11月30日星期日

The installation of the switch and outlet boxes and panel, connection is not in conformity with the requirements


 Stator And Rotor ac induction motor parts 

Specifications
1. 20 years manufacturing experience 
2. competitive price,high quality 
3. Material: silicon steel 
1, the phenomenon of electric motors (1), the box embedded too deep, different level; Panels and Water pump wall body between cracks, lac pollution, not flat. (2), box with mortar sundry. (3), phase line of switch and outlet, the zero lamination line, PE line are concatenated phenomenon. (4) the wires, switches, sockets thrum exposed, fixed bolt looseness, box conductor is absence. 2, root cause analysis (1), embedded box without reliable fixation, template expansion mode, installation time coordinates are not accurate. (2), construction personnel is not strong sense of responsibility, the use of electrical safety importance understanding insufficiency, the easier. (3), there is not reasonable to save material. 


Electric Motors 1 HP 3PH
Specifications
1. Shape: squirrel cage
2. CE.ISO CCC 
3. Side Terminal Box 
4. Free Foot Mounting 

5. 100% copper wire 
3, preventive measures (1), in close coordination with small diesel generator set diesel engine the civil engineering professional, accurate reliable fixed box; When embedded box is deep, should be equipped with a box. Installing a panel to horizontal flat vertical, application level calibration level, ensure the installation height of unity. In addition, diesel generator set after install panel to full seams, are not allowed to leave aperture, be clean protection panel. (2), strengthen supervision and management, ensure the phase switch and outlet line, zero line, PE line rotor and stator protection cannot be concatenated, clean up the first container of mortar. (3), fixed size when stripping, guarantee the thread tidy uniform, thread www.facebook.com/guohong.trading after installation not naked; To strong pressure wire at the same time, the single conductor when the insert line hole should be generator set spread into twin, screw tight, tight. (4), switch, socket box wires should have certain allowance, is 100-150 - mm; To resolutely put an end to the unreasonable material greed.

2014年11月18日星期二

Power frequency withstand voltage test

 Cast Iron electrical motor auto spare parts 
Specifications
1. 20 years manufacturing experience 
2. competitive price,high quality
3. Delivery Detail:within 10 days after receiving deposit 
Series resonance overvoltage withstand test device for the power frequency single phase motor withstand voltage test pressure (also called variable frequency series resonance devices or series resonance overvoltage withstand test equipment), is the latest generation, especially suitable electric motor low rpm for large capacity capacitive products (such as generator, cable, etc.) of ac withstand voltage test equipment. This is the product of simple operation, reliable quality, small volume, light weight, very convenient for use. The equipment can be used for 1, 6 kv, 500 kv ac acmotortrading.blogspot.com withstand voltage test of high voltage crosslinked cable 2, 3 generator ac withstand voltage test, ac withstand voltage test of GIS and SF6 switch 4, 6 kv, 500 kv transformer power frequency overvoltage withstand test 5, and other electric power high voltage equipment, such as bus, casing, ac withstand voltage test of transformer. The complete set of equipment is composed of variable frequency power supply, excitation transformer, reactor, voltage divider.

2014年10月11日星期六

Three-phase no-load current of 2.5 0.75 KW motor,what reason be


Two sets of 0.75 KW...Grade 4...380 v...The motor.No-load current is between 2.3 to 2.6...Work environment textile...'a lot...Rated current of the motor is only 2.2...Normal no-load current is around 1.6...Time machine completely under the condition of no load over current...Due to the current big.So high temperature sharply born...Will soon.motor magnet Overheating damage...Please say the reason...thank you Problem complement: I thank two answer first...Disease,and together,the two are not normal before.In a few years later.

You'll find the bad one current is increased.[.Repair of the motor are friends.Eliminate offline ribbon...Until now,with or without load...motor run capacitor Motor current is bigger...Last year when the motor current in 2.0 A...Now 2.4-2.5 A...Motor shaft sleeve inside and outside in good condition...Have not completed...Don't go...Just electric pilot time to run the old hot...Often the temperature in the 60-80 degrees...Wiring is right...electricalmotor1.blogspot.com Are the normal installation...There is a reason,is you pick the wrong wiring.380 v y connection.You make into 380 v delta connection.So,motor heat quickly.This is one of them.In addition,the machine is idle for motor vehicle a long time,must have certain load.If is in use after a period of time (excluding intervention had gone wrong),should be the result of mechanical failure.1 bearing damage increase torque resistance.Run 2 bearing outer ring,which leads to the bearing wear gaps (cover),the rotor eccentricity running and friction with the stator (boring),increase the torque resistance.

2014年8月12日星期二

Phase ac motor capacitor after the start and use?


The rotation of the single phase ac motor principle Only a single phase ac motor winding,is squirrel cage rotor.When a single-phase sinusoidal current in the stator winding,the motor can produce an alternating magnetic field,The magnetic field strength and direction of interplanting sine law of change at any time,but on the spatial orientation is fixed,so the magnetic field is also called alternation pulse magnetic field.The pay Variable pulse magnetic field can be decomposed into two at the same speed and direction of rotation are instead of a rotating magnetic field,when the rotor static,the two two rotating magnetic field in the rotor An equal and opposite torque,making synthetic torque is zero,so the motor can't rotate.When we use the motor rotates in the direction of a force (clockwise),then the rotation of the rotor and clockwise direction magnetic field between the cutting lines of magnetic force movement decreases; Rotor and the spin counterclockwise direction Turn the cutting lines of magnetic force between field.This balance is broken,the total electromagnetic torque generated by the rotor will no longer be zero,the rotor will spin down driving direction Turn up.To make single-phase acmotortrading.blogspot.com electric function automatically spin,we can add a starter in the stator winding,starting with the main windings in space by 90 degrees,starting Winding to concatenate a suitable capacitance,makes differ with on the phase of wholesalemotor.blogspot.com the primary winding current approximate 90 degrees,the so-called split-phase principle.These two are on time 90 degrees of electricity flow into motor lamination the two differ 90 degrees of winding on the space,will be produced in the space (two-phase) rotating magnetic field,under the effect of the rotating magnetic field,the rotor is Can automatic starting,after the start,to speed up certain,with the aid of an installed on the rotor of the centrifugal switch or other automatic control device will start winding disconnect,The only main winding work in normal working conditions.Therefore,starting winding can make short work.But there are a lot of time,starting winding is not broken,we induction motor refer to this Single-phase motor,motor for capacitive's turn to change this motor,can be achieved by changing the position of the capacitor is concatenated.

IE2 and IE3 high efficiency three phase electric motor

Filler cap Electric hammer,electric pick etc tools have filler cap,how is the plastic material,can be special wrench or low speed permanent magnet generatorcirclip pliers,long nose pliers in the filler cap two eyes spin down,convenient and filling. Filler cap of fault slip wire or motor parts untight seal,oil spill. Slide wire is not serious,can be wrapped around some ribbons,hemp rope,cord,etc.;Serious,convenient use thicker plastic bag on the filler cap,then tap with a hammer,can also be electricalmotor1.blogspot.com bound once or more times on electrician with black tape and then turned on. Looked at the untight seal,O ring aging,damage,loss,a new O ring should be replaced.