显示标签为“single phase ac motor”的博文。显示所有博文
显示标签为“single phase ac motor”的博文。显示所有博文

2014年11月19日星期三

Switch products of new technology in recent years



Cast Iron electrical motor auto spare parts 

Specifications
1. 20 years manufacturing experience 
2. competitive price,high quality

3. Delivery Detail:within 10 days after receiving deposit 
In the network packets of data flow can be respectively in 2, 3, or 4 layer for identification. Each layer will provide more detailed information about the data flow. In the second layer, each packet of data flow through the motor electric source site and destination MAC address is identified. Within the broadcast domain, layer 2 switching function is limited, this is because the source and destination MAC address is only account for a packet of information in a rough. Layer 2 switches can provide cheap and high bandwidth Internet connection, but they are unable to provide necessary control data flow of the trunk. In the third layer, the data flow through the source and destination network IP address is identified, the ability to control the data flow is limited to the source, ANP gost motor destination address.

gost motor 7.5kw
Specifications
1. effiency: IE2 and IE1 
2. 20 years manufacturing experience 
3. 12 months guarantee 

4. low noise and vibtration
 If a client is using multiple applications on the same server at the same time, the layer 3 information is not detailed description to each application flow, which makes it impossible to identify the different data streams, more can't one by one for each data flow to implement different control rules. The fourth floor is the transport layer of the OSI model. It is responsible for coordination of network communication between the source and destination system. TCP (transmission control protocol) and UDP (user datagram protocol) are located in the fourth floor. In the fourth layer, each packet contains can be used to identify only send the package information application. Can do this because the TCP and UDP header generator set contains "port", the port can determine each package contains application protocols. The port number of the layer 4 header information and the layer 3 header source - goal combination can realize accurate control of real information. Specific application dialogue can flow control between the client and the server, if the switching router is a full-featured, is all this work can be done at wire speed.

2014年11月12日星期三

Switching network



AC fan cooling motor fan cover 

Specifications
1. Customised 
2. good quality 
3. Surface treatment: Galvanize 

4. Type: Motor Cover 
 Repeaters to go in and out In and out of Repeaters is the interface circuit between the trunk and switching network, is used to switch trunk connections. Its features and circuit and switching system used in the system and trunk signal way has a close relationship between innings. To simulate relay interface unit (ATU), its role is to realize the simulation of the trunk and exchange network interface, basic functions in general are: sending and receiving said trunk status (such as idle, occupy, reply, release, etc.) of the line signal. Forward to receive on behalf of the called number of register signal. Supply the power supply and signal. Provide the received signal to control equipment. For the simplest case, a switch relay through solid line trunk with another switch connection, and USES the subscriber loop signal, then the simulation of the repeater function and equivalent to a "phone". If other more complex signal method, the repeater should implement the corresponding voice, signal transmission and control function.

 CCC,CE Certification and Waterproof Protect Feature ac motor
Specifications
power range: 0.12-18.5 kW 
Centre height of frame: 63-160 mm 
Rated Voltage: 220V 
Rated Frequency: 50Hz or 60Hz
Digital trunk interface unit (DTU) role is to realize the digital trunk and the interface between the digital switching network, it was related by PCM timeslot transmission trunk signaling, complete is similar to the basic function of the simulation should bear repeater. But as a result of the digital trunk transmission way of PCM digital signal, therefore it has some special issues of digital communication, such as frame synchronization, the clock recovery, type exchange, signaling insertion and extraction and so on, which to solve the signal transmission, synchronization and signaling with three aspects of the connection 3 phase induction motor problem. The basic function of digital acmotor2.blogspot.com ac motor relay interface unit including the frame and the complex frame synchronization code generation, frame, even zero suppression, type transformation, alarm processing, clock recovery, frame synchronization search and inter-office signaling insertion and extraction etc., like permanent magnet motor BORSCHT simulated user circuit, also the above eight kinds of function of digital relay unit can be summarized as GAZPACHO.

ZC25B - 4 test three-phase insulation insulation resistance meter

 generator Stator Rotor 
Specifications
1. 20 years manufacturing experience 
2. competitive price,high quality 
3. Accessories Series: stator and rotor
ZC25B - 4 type insulation resistance meter test three-phase insulation. The insulation ac electric motor resistance tests measuring leakage current between the two wires. So need to put the two clip sandwiched between two wire line core. (shaking table on the grounding wire don't let it empty) wire core yellow green, A and B are measured relative phase of the insulation resistance between A to B. Red line core green B and C, the Induction motor relative phase between measurement is B to C is insulation resistance. The wire core is A and C, the measurement of the insulation resistance is A relative phase between the C. Wire core A and N, insulation resistance measurement is A relatively is zero. A line core with PE, the insulation resistance measurement is A relatively. And so on. 1 kv under low pressure, the test ZC23 or 25, two clip clamp respectively clean two conductor, from slow to quick turn the crank, about 120 r/min, maintain uniform, pointer corresponding calibration is insulation resistance magnet generator value. Such as refers to 200, is 200 ohms.

2014年9月17日星期三

The similarities of stepping drive way

If readers are smart,or very careful when practice,maybe you will note that single polar stepper motor and bipolar stepper motor on the stepper drive mode is very similar.As described above the single polarity of stepper motor step way form,for example,by exchanging electricalmotor1.blogspot.com the positions of the column and column C B,all the "tong" replace with "+",then in the lead with status to "+" in another column of the same winding up ".",will see and bipolar stepper motor in the same format on the form,only motor to the electric motors 12 voltopposite.This shows that any logic control single polar stepper motor can also be
used to drive a bipolar stepper motor.Pay attention to is the logic,rather than drive circuit.Bipolar
magnetic generator stepper motor windings need H bridge circuit,and the single polarity stepper motor only need a simple transistor switch.Do in single polar stepper motor control and switch between single phase asynchronous motorbipolar stepper motor,the only change is the exchange of B and C need logic output.

Motor points for attention


(1) before disassembly,should surface dust with compressed magnet generator air
blowing off the motor,and scraped clean surface dirt.2 choose motor working place,the disintegration of the clean up the scene environment.(3) familiar with acmotor2.blogspot.com the
motor structure characteristics and maintenance technical requirements.(4) ready to collapse the
required tools and equipment (including special tools).5] in 220v electric motor
order to further understand the defects of the motor running,conditional when can do an inspection test before disassembly.For this,turn motor with load test,the detailed check parts,such as temperature,sound,vibration motor,and test the voltage,current,speed,etc.,and then disconnect the load,do a no-load check test,no-load loss and no-load current is measured and recorded.

[6] to cut off the power supply,electrical wiring to remove,recorded.Once the appropriate voltage test motor insulation resistance by megger are.Maintenance in order to keep pace with electric motors price .The Times when measured insulation resistance compared to determine the motor insulation change trend and insulating state,should be measured under different temperature insulation resistance value of the conversion to the same temperature,the average conversion to 75 ℃.Being tested to absorb than K.When the absorption ratio greater than 1.33,which indicates that the motor insulation or degree of be affected with damp be affected with damp be affected with damp be affected with damp or not serious.In order to compare with previous data,also want to add any temperature measured absorption than the conversion to the same temperature.