2 it is to consider at low frequency,in order to improve the output torque and appropriate to increase the output voltage of inverter. 2,the structure design Structure design,main is also considering the non-sinusoidal power characteristics of variable frequency motor insulation structure,the influence of vibration and noise cooling mode,generally pay attention to the following questions: 1) the insulation class,generally for perkins diesel generator set F or higher,strengthen the insulation and line turn insulation strength,especially want to consider the ability of impact resistance voltage insulation. 2) to the problem of vibration and noise of the motor,the motor should be fully considered component and overall rigidity,trying motor lamination to improve its natural frequency,in order to avoid and every force wave resonance phenomenon. 3) cooling method: generally adopts the forced ventilation cooling,namely USES the independent main motor cooling fan motor driver. 4) measures to prevent shaft current,the capacity of more than 160 kw motor bearing insulation measures should be adopted. Mainly produces magnetic circuit asymmetry,also can produce shaft current,while the rest of the high frequency component generated by the current role in combination,shaft current will increase greatly,which can lead to bearing damage,so often insulation measures. 5) www.facebook.com/guohong.trading to the constant power variable frequency motor,when the rotation speed of more than 3000 / min,high temperature resistant special grease should be adopted,to compensate for the temperature of the bearing