显示标签为“12v motor”的博文。显示所有博文
显示标签为“12v motor”的博文。显示所有博文

2014年11月17日星期一

How much is the no-load current of asynchronous motor?


electric motor stator rotor lamination motor parts 

Specifications
1. Lamination of electric motor 
2. IP54 class F 
3. 100% copper 
4. silicon steel stamping 

5.stunning performance 
Formula is the scene quickly calculate motor no-load current of specific numerical formula, it is a lot of ac electric motor the test data. It is in line with "the no-load current of the motor is the 1/3 of its rated current". At the same time it is in line with practice experience: "the no-load current of the motor, shall not exceed the capacity of the kw number can be used for" the principle of (after repair of old, small capacity motor). Formula "capacity by about eighty percent for" refers to the general motor no-load current value is about 0.8 times the number of nominal capacity kw electric motor low rpm motor. No-load current of medium-sized, 4 or 6 pole motor, is the number of motor capacity kw 0.8 times; New series, large capacity, small number of level 2 of the motor, the no-load current calculation according motor electric to the number of "xinda sixty percent less"; To the old, old series, smaller volume, the number of large more than 8 pole motor, the no-load current, calculated on "is a small number of very many kilowatts", namely the no-load current value kw number approximately equal capacity, but is generally less than kilowatts.

2014年10月27日星期一

Three-phase no-load current of 2.5 0.75 KW motor,what reason be



Two 0.75 KW..Grade 4...380 v...The motor..No-load current is between 2.3 to 2.6...Work environment textile factory..'a lot...Rated current of the motor is only 2.2...Normal no-load current is around 1.6..Time machine completely under ac electric motor the condition of no load over current...Due to the current big.So high temperature sharply born..Will soon..Overheating damage..Do not say the reason...thank you Problem complement: I thank two answer first..Disease,and together,the two are not normal before..In a few years later.You'll find the bad one current is increased.[.Repair of the motor are friends.Eliminate offline ribbon..] ...Until now,with or without load..Motor current wholesalemotor.blogspot.com is bigger...Last year when the motor current in 2.0 A..Now 2.4-2.5 A...Motor shaft sleeve inside and outside in good condition...Have not completed...Don't go...Only electricity pilot time to run the old hot..Often the temperature in the 60-80 degrees...Wiring is right...Are the normal installation... 


There is a reason,is you pick the wrong wiring.380 v y connection.You make into 380 v delta connection.So,motor heat quickly.This is one magnetic generator of them.In addition,the machine is idle for a long time,must have certain load.If it is in use for a period of time after the scenario (excluding intervention had gone wrong),should be the result of mechanical failure.1 bearing damage increase torque resistance.Run 2 bearing outer ring,which leads to the bearing wear gaps (cover),the rotor eccentricity running and friction with the stator (boring),increase the electric motor 12v 500w torque resistance.What type of your motor,then measure the core size,what are you friends with line,around a few laps? I help you check it.Is estimated to be between winding insulation damage,it is recommended that you access the winding.

Dc braking principle

Dc braking principle. When asynchronous motor stator winding zhongtong into direct current, the magnetic field generated by the constant magnetic field will be the space www.facebook.com/guohong.trading position unchanged, and the speed of the rotor because of its inertia continues with its original spin, at this point, the rotation of the rotor cutting the static magnetic field and produce brake torque, system stored kinetic energy is ac motor converted into electrical energy consumption in the rotor circuit of the motor, thus to achieve the effect of fast brake motor. In order to guarantee the safety of the motor, dc brake is best used with braking energy. Inverter dc brake setting, dc fan motor brake basically set the following three contents 2.1, started to dc brake starting frequency 2.2, applied to the stator winding voltage dc brake. As a result of the stator winding dc resistance is very small, so lamination the dc brake voltage adjusting range is usually the circuit dc voltage of the 0 ~ 10%; 2.3, the braking time. Braking time impossible and actual braking time coincide, in order to ensure the braking effect, usually set slightly larger;

2014年9月22日星期一

Two single polar stepper motor


This kind of stepper motor is referred to as the single polarity because each winding current to flow along one direction only.It is also referred to as the two line stepper motor,because it only contains two coils.The reverse polarity,two coil winding on the same core,with the same intermediate tap.Single polar stepper motor also referred to as 4 phase stepper motor,because it has four excitation winding.Single polarity of stepper motor fuses have 5 or 6.If the leads of the stepper motor is 5 root,then one of them is connected to the public line f v +),the other four phase 4 root respectively connected electricalmotor1.blogspot.com to the motor.If the leads of the stepper motor is 6,so it is more sections of a unipolar stepper motor has two windings,each winding have asked tap in a lead.But how to distinguish the lead? Please continue to read the following content.Distinguish line 6 single polar stepper motor joint recycling old printer when most often encounter this type of unipolar stepper motor.

Line 6 single polar stepper motor usually permanent magnet generators for sale looks like two single sections of stacked together,each single section has three lines elicit f see figure 6).This is a very easy to distinguish the leads of the stepper motor.Distinguish between 6 line stepper motor fuses order work is quite simple.If it is the structure of many sections of stepper motor,then the order of the lead has actually been given,with the digital multimeter can identify each public line of winding.Just keep winding for two fuses corresponding ac electric motors consistent,it doesn't matter whether they order only affects the direction of rotation of motor.If not more 3 phase motor sections of six lines of stepper
motor,can press the following steps to determine winding lead: (1) using a digital multimeter find public side each pair of windings.(2) according to the above methods can find two winding,separating them and marked.Please send one winding of marked A and C (also can be l and 3),another tag for B and D (can also be A 2 and 4).In each pair of windings,which fuses what order is not important,as long as
the pair is enough.

2014年8月27日星期三

Efficiency more than eighty percent of the permanent magnet motor


Efficiency more than eighty percent of the permanent magnet motor product 2~3% lower than the foreign advanced level,the expert suggests to improve Chinese permanent magnet motor 220v ac electric motors system energy efficiency.At present in China,permanent magnet motor power consumption accounted for about 60% of the national power consumption,small and medium-sized motor account for 80% of the national power of the motor. China's motor system energy saving a huge promotion potential,improve the energy efficiency of acmotor2.blogspot.com small and medium-sized motor,is an important aspect of an industrial terminal equipment and energy
saving.
China will become the world's largest production base of system components,motor and motor
improve motor system energy efficiency,China is not only beneficial to China's economy,as well as
sustainable energy supply in the international market. ac geared motor If China in 2020,all use high efficiency motor,can reduce 20.8 billion tons of carbon dioxide emissions into the atmosphere each year and 78.09 million tons of sulfur dioxide. The national development and reform commission energy research institute,the renewable energy development center,deputy director of the proposal,countries should speed up related policy incentives and punishment measures,make enterprise 220v ac electric motors need to weigh the efficiency in using the motor.

2014年8月21日星期四

Output voltage space vector method


In direct torque control,if we can get any phase of space voltage vector,will help to reduce the
torque ripple under low-speed,reach the steady state performance of vector control at low speeds.In the third quarter no beat control can get any phase of space voltage vector,but calculation is more complex,more difficult.Another for any phase of space voltage vector method is to use PI regulator.A.b.induction motor salesPlunkett direct torque and flux adjustment method is A kind of PI adjustment method,only then had not space voltage vector this concept,can only use the method of SPWM output voltage motor control.In the literature,the proposed method of direct torque control using PI control,and output space voltage vector for the SVM method. Obtained by torque and torque feedback given error input torque PI controller,PI adjustment get q axis acmotortrading.blogspot.com voltage vector and stator flux and stator flux feedback given by the gain of the stator flux linkage error input PI regulator,PI regulation to obtain d shaft voltage vector,then d axis and q axis voltage vector rotation transform the alpha shaft under the static coordinate system and beta,used for the output of the space voltage vector,clearly the space voltage vector in the phase space position is arbitrary.

Structurally similar direct torque control based on PI control on the stator flux vector control,but there is a difference between the two,the stator flux vector control based on synchronous rotating coordinate system,the stator flux orientation in d axis,q axis flux is zero in the d axis direction and the flux and q axis direction of current decouple,and these for direct torque control based on PI control does not need to,among them only need to make the output torque and stator flux feedback can be given by PI regulating method to follow,so from the implementation is relatively simple,robustness is also good at the same time,and compared with the traditional gasoline generator spare parts direct torque control can improve the switching frequency,reduced torque ripple under low-speed,but in this method need to select the right PI parameters,otherwise it will affect the control system dynamic and static performance.In addition to the above this kind of PI control of direct torque control,also in the literature in a.b.Plunkeet direct torque and flux control method on the basis of further research,the use of space voltage vector way output,not detailed here.